Executive Summary
GenAI Protos benchmarked four open medical vision-language models, NVIDIA's NV-Reason-CT, Google's MedGemma 1.5, Hulu-Med 7B and Astra, on how closely their chest CT reports match what radiologists found. Each model ran exactly as published, in its own environment on an NVIDIA DGX Spark, on the same 11 chest CT scans from ChestPathCT5, a dataset none of them was trained or tested on. An AI judge labelled all 44 reports blind, then scored them against 34 radiologistconfirmed findings. NV-Reason-CT came closest, finding 17 of 34 with no false findings (MicroF1 0.667), ahead of MedGemma 1.5 (0.444), Hulu-Med 7B (0.400) and Astra (0.326). The result is a first direction from a small research study, not a clinical result.
01Problem Statement
Open medical models report strong scores on large datasets like CT-RATE, but those scores are worked out against labels made by RadBERT, a model that reads the report text and marks the findings it mentions. That measures agreement with another model, not with a radiologist. Finding out which model truly reads a chest CT best needed a benchmark that could provide:
- A test set that none of the four models had been trained or tested on
- Ground truth confirmed by radiologists, not labels extracted by another model
- Each model run as published: original weights, official preprocessing, no fine-tuning
- One shared way to run, save and time every report, so results are comparable and traceable
- A score that penalises invented findings as well as missed ones
02Our Approach
We built the benchmark around one rule: take the original models, change nothing, and test them on the same examples.
- Dataset with real ground truth: ChestPathCT5-S100 (CHUV Lausanne, CC0) has 87 chest CTs; the 11 with three or more radiologist-confirmed findings gave 34 findings across pneumothorax, pleural fluid, lung mass, rib fracture and pulmonary embolism.
- Isolated model environments: each model was loaded onto the DGX Spark in its own Python environment with its own official preprocessing, so no setup on the shared machine was disturbed and no model was forced into a pipeline it wasn't built for
- One batch console: selects the scans and models, asks each model only for a structured chest CT report, and saves every report the moment it is written with a timestamp, run time and any error
- Blind judging: Claude Fable 5.2, in a separate chat, read all 44 reports without the ground truth and marked which of the five conditions each report states, quoting the exact sentence.
- Scoring against radiologists: only then was the ground truth shown, and every finding was counted as found, missed or wrong to produce a found score and Micro-F1.

The four models, side by side
| NV-Reason-CT | MedGemma 1.5 | Hulu-Med 7B | Astra | |
|---|---|---|---|---|
| Built by | NVIDIA | Google Health AI | Zhejiang University | zh-Wang-Med |
| Size | 4.69B parameters | 4B parameters | 7B parameters | 7B writer |
| How it sees the scan | Whole scan as one 3D volume: 2 mm voxels, 38.4 cm cube, 192 × 192 × 192 | 85 evenly spaced slices, each in 3 CT windows as colour | 180 axial slices, the official 3D setting | Whole volume cropped to the body, 224 × 224 × 160, one window (−1000 to 200 HU) |
| Image encoding | 3D vision transformer (COLIPRI), 13,824 image tokens | MedGemma image encoder | Vision encoder, drops repeated tokens (about 55% fewer) | Merlin 3D encoder + Perceiver, 32 tokens |
| Report writer | Qwen3.5-4B, reasons step by step first | MedGemma 1.5 language model, up to 2,000 tokens | 7B language model, up to 1,024 tokens | Qwen2.5-VL-7B, organ by organ in 11 fixed regions |
| Prompt | Structured chest CT report | Structured chest CT report | Structured chest CT report | Astra's own chest prompt |
| Trained on CTRATE | Yes | No | No | Yes |
| GPU memory | ~15 GB | ~10 GB | ~27 GB | ~20 GB |
03Outcome
- NV-Reason-CT came closest to the radiologists: Micro-F1 0.667, 17 of 34 findings found and no false findings.
- MedGemma 1.5 placed second with Micro-F1 0.444, and was the strongest model on pleural fluid (9 of 10).
- Hulu-Med 7B scored 0.400 (9 found, 2 false findings) and Astra 0.326 (7 found, 2 false findings).
- Pneumothorax: NV-Reason-CT caught it in 7 of 8 scans; every other model found it in only 1 of 8.
- Pulmonary embolism was missed by every model, and Astra reported a PE twice where there was none.
- 44 reports generated and traced: each saved with its timestamp, run time and errors, downloadable per model.
- Original models, unchanged: no fine-tuning; each with its official preprocessing on a single DGX Spark.
- A repeatable benchmark pattern: isolated environments, one batch console and blind judging, reusable on new models or new data.
| Model | Found | Missed | Wrong | Found score | Micro-F1 |
|---|---|---|---|---|---|
| NV-Reason-CT | 17 | 17 | 0 | 0.50 | 0.667 |
| MedGemma 1.5 | 10 | 24 | 1 | 0.29 | 0.444 |
| Hulu-Med 7B | 9 | 25 | 2 | 0.26 | 0.400 |
| Astra | 7 | 27 | 2 | 0.21 | 0.326 |
What each model found, by condition
| Model | Pneumothorax (8) | Pleural fluid (10) | Lung mass (5) | Rib fracture (10) | Pulmonary embolism (1) |
|---|---|---|---|---|---|
| NV-Reason-CT | 7/8 | 7/10 | 2/5 | 1/10 | 0/1 |
| MedGemma 1.5 | 1/8 | 9/10 | 0/5 | 0/10 | 0/1 |
| Hulu-Med 7B | 1/8 | 5/10 | 2/5 | 1/10 | 0/1 |
| Astra | 1/8 | 5/10 | 0/5 | 1/10 | 0/1 |
04Screenshots
05Tech Stack & Ecosystem
Key models, frameworks, and core infrastructure powering this solution.
NV-Reason-CT (NVIDIA, 4.69B), MedGemma 1.5 (Google, 4B), Hulu-Med 7B (Zhejiang University) and Astra (Merlin encoder + Qwen2.5-VL-7B), all used as published. NVReason-CT, MedGemma and Astra run in bf16
NVIDIA DGX Spark (GB10) with 128 GB unified memory. Models run one after another, never side by side.
Ubuntu 24.04.3, ARM64, NVIDIA driver 580.95.05, CUDA 13.0, PyTorch 2.11.0+cu130, with a separate Python environment per model. Hulu-Med needed a small runtime patch to encode its 180 slices one at a time instead of allocating over 200 GB, plus a locally built ARM64 decord; no model file was edited.
ChestPathCT5-S100, CHUV Lausanne, CC0 licence. NIfTI (.nii.gz) chest CTs in HU; the same file goes to every model.
Claude Fable 5.2 in a separate chat. Labels blind with quoted evidence first, then scores against the radiologist ground truth with the same rules for every model.
Selects scans and models, launches runs and collects reports. Each run gets its own timestamped folder with the report text, the input the model saw, run time and errors.
06Client Testimonials
“GenAI Protos helped us move beyond published benchmark scores by creating a structured evaluation of four medical AI models against radiologist-confirmed chest CT findings. Their team set up consistent testing environments, automated report collection, and a blind evaluation process, giving us a clearer understanding of each model's strengths, missed findings, and limitations. The results gave us a practical starting point for further research and evaluation.”